02
Ultrasonic & Volumetric Inspection
UT, Advanced UT and TOFD for thickness measurement, internal flaw detection and detailed weld inspection.
ExploreConventional and advanced Non-Destructive Examination under one scope — led by Phased Array Ultrasonic Testing, and selected around the equipment, the damage mechanism and the decision the data has to support.
Core Capability
Electronically steered, focused and encoded ultrasound that images the full weld volume in a single pass. PAUT is the centre of our capability — it replaces radiography on most weld applications, detects and sizes the planar flaws that matter, and leaves a permanent record that can be re-read at the next outage.
Most scopes need more than one method. We run the combination rather than fitting the asset to a single technique.
02
UT, Advanced UT and TOFD for thickness measurement, internal flaw detection and detailed weld inspection.
Explore
03
Specialized inspection of tubes, heat exchangers, boilers and condensers using IRIS, Eddy Current and Surface Array techniques.
Explore
04
Magnetic Particle and Penetrant Testing, supported by rope-access capability for difficult-to-reach areas and structures.
Explore
05
Advanced inspection for specific damage mechanisms, including High-Temperature Hydrogen Attack in critical refinery and chemical-processing equipment.
ExploreA quick reference for matching the technique to the problem. If you are not sure which applies, send us the scope and we'll advise.
| Method | What it finds | Typical application | Service |
|---|---|---|---|
| PAUT — Phased Array UT | Planar flaws, cracks, lack of fusion, metal loss; with through-wall sizing | Weld examination, corrosion mapping, crack sizing | Phased Array Testing |
| UT — Conventional | Wall thickness, laminations, internal flaws | CML surveys, remaining-wall checks, lamination screening | Ultrasonic & Volumetric |
| TOFD | Flaw tip diffraction; accurate through-wall height | Long weld coverage and flaw sizing | Ultrasonic & Volumetric |
| AUT / Corrosion mapping | Metal loss distribution and minimum remaining wall | Erosion profiling, trending between outages | Ultrasonic & Volumetric |
| IRIS | Absolute wall thickness around the full tube circumference | Heat exchanger, boiler and condenser tubes | Tube & Electromagnetic |
| Eddy Current (ECT) | Pitting, wall loss and cracking in non-ferrous tubing | Full-bundle screening on condensers and air coolers | Tube & Electromagnetic |
| Surface Array / ECA | Surface and near-surface cracking, through thin coatings | Welds and component surfaces without stripping paint | Tube & Electromagnetic |
| MT — Magnetic Particle | Surface and slightly subsurface flaws in ferromagnetic material | Weld toes, fillet welds, structural connections, lifting gear | Conventional & Access |
| PT — Liquid Penetrant | Surface-breaking flaws in non-porous materials | Stainless, aluminium and non-ferrous components | Conventional & Access |
| HTHA assessment | High-temperature hydrogen attack and mechanism-specific damage | Hydroprocessing equipment and hot hydrogen piping | Specialized Damage |
Procedures are written to the governing code and acceptance criteria, or to your own written practice where you operate one.