Specialized Damage Detection
Advanced inspection for specific damage mechanisms, including High-Temperature Hydrogen Attack in critical refinery and chemical-processing equipment.
A good thickness reading is not a clean bill of health.
Some damage mechanisms do not announce themselves as a straightforward wall-loss or weld-flaw problem. High-Temperature Hydrogen Attack is the clearest example: it develops as microscopic fissuring at the grain boundaries, deep inside apparently sound material, and a conventional thickness survey will read the wall as perfectly good right up until the component fails.
Detecting mechanisms like this is not a matter of running one more technique. It starts with the service conditions — temperature, hydrogen partial pressure, material grade, time in service — and with the corrosion study or damage mechanism review that tells you what the equipment is actually susceptible to. The inspection is then designed around that susceptibility.
We scope and deliver that work: the right combination of advanced ultrasonic techniques, applied at the locations where the mechanism is credible, with a baseline that later inspections can be trended against.
High-Temperature Hydrogen Attack
HTHA occurs when atomic hydrogen diffuses into carbon and low-alloy steel operating at elevated temperature and hydrogen partial pressure. Inside the steel it reacts with carbides to form methane, which cannot diffuse back out. Pressure builds at the grain boundaries, producing internal fissuring and decarburisation, and progressively destroying the strength and toughness of the material.
The susceptibility limits are set out in API RP 941 and its Nelson curves. The equipment most commonly at risk sits in hydroprocessing service — hydrotreaters, hydrocrackers, catalytic reformers, hydrogen reformers and the associated hot piping, with welds and heat-affected zones among the first areas to show damage.
No single technique reliably detects HTHA at every stage. Early-stage micro-fissuring, advanced fissuring and gross damage each respond differently, so credible detection means applying several complementary ultrasonic measurements over the same area and reading them together.
Several measurements, read together.
Each technique on its own can be ambiguous. Applied over the same volume and correlated, they make a defensible call.
TFM / FMC imaging
Full Matrix Capture with Total Focusing Method reconstruction focuses at every point in the image rather than at one preset depth — the highest-resolution ultrasonic view available of micro-fissuring and clustered damage.
Multi-mode phased array
Phased array applied across several wave modes and angle ranges over the same volume, so damage that is invisible at one orientation is picked up at another.
Backscatter measurement (AUBT)
Advanced Ultrasonic Backscatter Technique looks at the noise between the front and back wall signals. Fissuring scatters sound, and the backscatter signature changes before any wall loss appears.
Velocity ratio
The ratio of shear to longitudinal velocity shifts as bulk damage accumulates — a bulk-material indicator that is independent of surface condition.
Attenuation & spectrum analysis
Measuring how much the material absorbs and how the frequency content changes with depth, giving a further independent line of evidence.
Baseline & trending
An encoded, repeatable baseline at defined locations, so the next inspection measures the same volume and the comparison is meaningful rather than anecdotal.
Damage we are asked to find.
The inspection follows the mechanism. Tell us the service conditions and we'll tell you what is credible and how to look for it.
| Damage mechanism | Where it occurs | How we approach it |
|---|---|---|
| High-Temperature Hydrogen Attack (HTHA) | Carbon and low-alloy steel in hot hydrogen service — hydrotreaters, hydrocrackers, reformers | Combined TFM/FMC, multi-mode PAUT, backscatter and velocity ratio at susceptible welds and HAZ |
| Hydrogen-induced and stepwise cracking (HIC / SOHIC) | Wet H₂S service, sour water systems, amine units | Angled and multi-mode ultrasonic scanning for mid-wall planar and stepwise damage |
| Creep damage | High-energy piping, headers and hot components operating in the creep range | Targeted ultrasonic examination at welds and HAZ, with hardness support where required |
| Erosion and flow-accelerated corrosion | Elbows, tees, reducers, control valve downstream, two-phase lines | Encoded corrosion mapping to profile the loss pattern rather than spot-read it |
| Sulphidation and high-temperature thinning | Crude and vacuum heater passes, transfer lines, hot piping circuits | Structured thickness surveys with mapping where the loss is non-uniform |
| Clad and weld overlay disbonding | CRA-clad vessels, overlay-protected nozzles and internals | Phased array examination of the bond line across the clad area |
Worked to the code that governs your asset.
Specialised examination is planned against the recommended practice governing the mechanism and reported so it can feed directly into a fitness-for-service assessment.
What you receive.
Every job closes with documentation your engineering, reliability and integrity teams can file, audit and act on.
- Inspection plan built from the damage mechanism and service conditions
- Examination location drawings tied to identifiable reference points
- Encoded data from each technique applied over the same area
- Correlated interpretation reading the techniques together, not separately
- Damage classification and extent, with imagery supporting the call
- A repeatable baseline for future trending
- Data in a form suitable for fitness-for-service assessment input
- Signed report with a clear statement of what was and was not covered
Equipment operating above the Nelson curve?
Send us the service conditions and material grades — we'll scope an HTHA inspection that stands up to review.