Ultrasonic & Volumetric Inspection
UT, Advanced UT and TOFD for thickness measurement, internal flaw detection and detailed weld inspection — scoped to the damage mechanism, not to a single technique.
What the wall is doing, and what is inside it.
Ultrasonic testing is the backbone of volumetric inspection: sound is introduced into the component, and what comes back tells you how thick the wall is and whether anything inside it should not be there. We run the full range — from straight-beam thickness readings on a corrosion monitoring circuit through to encoded automated scanning and Time of Flight Diffraction on critical welds.
Most assets need more than one of these. A piping circuit might take conventional thickness readings at established condition monitoring locations, encoded corrosion mapping where the readings start trending, and TOFD or phased array on the welds. We scope the combination against the damage mechanism rather than selling a single technique.
All thickness and flaw data is referenced to identifiable locations so that the next inspection measures the same spot and the trend actually means something.
The methods we run.
Selected against the asset, the access and the mechanism you are managing.
Conventional UT (straight beam)
Zero-degree thickness measurement and lamination screening. The workhorse for condition monitoring location surveys, remaining-wall checks and pre-weld lamination clearance.
Shear wave / angle beam UT
Refracted angled beams for weld examination and crack detection where access allows only manual scanning, or where the geometry rules out an encoded setup.
Advanced & automated UT (AUT)
Encoder-driven scanning that produces a positional record rather than a list of spot readings — corrosion mapping, erosion profiling and repeatable outage-to-outage comparison.
Time of Flight Diffraction (TOFD)
A transmit-receive pair straddling the weld picks up signals diffracted from flaw tips. Fast coverage of long welds and the most accurate through-wall height measurement available.
Corrosion mapping
Gridded or raster scanning producing a C-scan thickness map — the minimum remaining wall, its exact location and the shape of the metal loss around it.
Thickness surveys to CML
Structured condition monitoring location surveys for API 510, 570 and 653 programmes, delivered in a format your integrity software can ingest.
Two techniques that cover each other's blind spots.
TOFD and phased array are complementary, not competing. TOFD gives excellent through-wall sizing and very fast coverage along a weld, but has a near-surface dead zone and is less reliable on transverse flaws. Phased array covers the near surface and the weld volume at multiple angles, and handles awkward geometry.
On critical welds we commonly run both: TOFD for the primary length coverage and sizing, phased array to clear the root, the cap and the near-surface band. Where the code allows the combination, this is the most defensible ultrasonic examination available without radiography.
Equipment we inspect.
- Pressure vessel shells, heads and nozzle welds
- Process piping circuits and condition monitoring locations
- Above-ground storage tank shells, annular plates and floors
- Boiler and high-energy piping welds
- Structural steel and heavy weldments
- Erosion and flow-accelerated corrosion profiling
- Lamination screening before hot work or weld repair
- Flange faces, bolting and studs
- New fabrication and pre-service baseline surveys
- Repair verification and post-weld examination
Worked to the code that governs your asset.
Thickness and flaw data is reported against the acceptance criteria in the code governing the asset, or against your own written practice.
What you receive.
Every job closes with documentation your engineering, reliability and integrity teams can file, audit and act on.
- Thickness survey data referenced to identifiable CML points
- Minimum, maximum and average remaining wall per component
- C-scan thickness maps with the minimum remaining wall located
- TOFD and encoded scan data files on request
- Indication tables with position, length and through-wall height
- Assessment against the governing acceptance criteria
- Trend comparison against previous inspection data you supply
- Signed report in your document control format
Need a thickness programme or a weld scope covered?