Phased Array Ultrasonic Testing
Electronically steered, focused and encoded ultrasound that images the weld volume in real time — and leaves you a permanent record of what was found and exactly where.
Imaging the weld, not guessing at it.
Phased Array Ultrasonic Testing is the core of what we do. A phased array probe holds an array of individually pulsed piezoelectric elements. By varying the firing delay across those elements, the sound beam is electronically steered, swept and focused — without physically moving or changing the probe. The result is a live cross-sectional image of the material under the wedge, not a single trace to interpret.
That difference matters on real assets. A single encoded pass over a weld captures the full volume at multiple angles, positions every indication in three dimensions, and stores the raw data so the inspection can be reviewed, re-analysed or compared against a later outage without going back to site.
We apply PAUT to weld examination, encoded corrosion mapping, crack detection and through-wall sizing across pressure equipment, piping and structural steel — in fabrication, at commissioning, and in live operating plant.
What phased array gives you that a single-probe shot does not.
No radiation, no exclusion zone
PAUT replaces radiography in most weld applications. No source, no barriers, no night shift, no stand-down of surrounding crews — the work around you keeps running.
Results at the probe
Indications are seen and assessed as the scan is performed. Repairs can be marked and re-inspected the same shift instead of waiting on film processing or an off-site read.
Planar flaws found and sized
Lack of fusion, lack of penetration and cracks are oriented badly for radiography and well for angled ultrasound. PAUT both detects them and measures their through-wall height.
A permanent, re-readable record
Encoded data is stored with positional information. A third party can re-analyse the file, and the next outage can be compared directly against this one.
Difficult geometry covered
Nozzles, branch connections, set-on and set-through welds, dissimilar metal joints and clad components are handled by building the scan plan around the geometry.
Fewer people, less disruption
A compact crew with a scanner and an encoder covers ground quickly, with no scaffolding footprint where rope access or temporary platforms will do.
Scan configurations we deploy.
The scan plan is built around the joint geometry, the material and the flaw type you actually need to find.
| Scan type | How it works | Typically used for |
|---|---|---|
| Sectorial scan (S-scan) | The beam sweeps through a range of refracted angles from one probe position, producing a fan-shaped image of the weld volume. | Butt and girth welds, nozzle welds, crack detection and height sizing. |
| Linear scan (E-scan) | A fixed angle is stepped electronically along the length of the array as the probe is moved. | Thick-wall welds, long seams, corrosion and erosion along a run of pipe. |
| Encoded corrosion mapping | A raster or line scan with a position encoder builds a C-scan thickness map of the scanned area. | Internal and external metal loss, erosion patterns, remaining wall profiles. |
| PAUT paired with TOFD | Phased array coverage combined with Time of Flight Diffraction for independent through-wall sizing. | Code-compliant weld examination where accurate flaw height governs the fitness-for-service decision. |
Where we apply PAUT.
From a single critical weld to a full turnaround weld population.
- Butt, girth and seam welds in pipe, vessels and tanks
- Nozzle-to-shell, branch and set-on / set-through connections
- Dissimilar metal welds and corrosion-resistant alloy cladding
- Encoded corrosion mapping and remaining-wall profiling
- Crack detection and through-wall height sizing
- Flange faces, studs, bolting and threaded connections
- Lamination and mid-wall discontinuity screening
- Pre-service baselines and repeat in-service monitoring
- Structural steel connections and heavy fabrication
- Weld overlay and clad bond integrity
Worked to the code that governs your asset.
Procedures are written to the code and acceptance criteria that govern your equipment, and we will work to your own written practice and client specification where you have one.
What you receive.
Every job closes with documentation your engineering, reliability and integrity teams can file, audit and act on.
- Written scan plan and technique sheet before mobilisation
- Calibration and verification records for every setup
- Encoded raw data files, supplied on request
- Indication table: position, length, depth, through-wall height, amplitude
- Annotated S-scan and C-scan imagery for each reportable indication
- Accept / reject assessment against the governing acceptance criteria
- Repair map and post-repair re-inspection results
- Signed report, issued to your document control format
Need a weld population covered without radiography?
Send us the joint details, material and thickness and we'll come back with a scan plan and a quote.